LACT Units

PESCO Builds High Quality LACT Units for Accurate Measurement and Custody Transfer of Crude Oil
We have customizable, flexible designs as well as standard designs. All designs can be built to meet our customer’s unique requirements. Our 2”, 3”, and 4” truck loading, truck offloading, and pipeline delivery LACTS are reliable and low maintenance. We use only high quality components and materials, enabling us to provide a quality, cost-effective product.
PESCO LACT AUTOMATION
- State-of-the-art control technology
- LACT controls can be integrated with customer’s existing system and software
- Custom programming available to meet customer’s specific needs
LACT TYPES
- Truck Loading
- Pipeline Delivery
- Truck Offloading
- Warm and Cold Weather Packages Available
LACT CAPACITIES
- 2” 3,600 BPD
- 3” 8,600 BPD
- 4” 14,000 BPD
Standard LACT Unit Components
- Inlet Block Valve
- Inlet Basket Strainer with DP Gauge
- Centrifugal Charge Pump with Electric Motor
- BS&W/Water Cut Monitor
- Air Eliminator
- Inline Static Mixer
- Automated Sample System
- Sample Pot with Pump, Static Mixer, Sample Drawo ff
- 3-Way Divert Valve (Bad Oil)
- Divert (Bad Oil) Line with Back Pressure Regulator and Block Valve
- Flow Meter – Coriolis or PD of your choice
- Pressure Transmitter
- Temperature Transmitter
- SS Thermowell for Meter Proving
- Meter Proving Connections with Double Block and Bleed Valve
- Back Pressure Regulator
- Outlet Check Valve
- Outlet Block Valve
- Liquid Filled Pressure Gauges
- Diamond Plate Floor with Drip Lip and Catch Basins
Available LACT Units
COLD WEATHER LACT:
- Truck Loading
- Pipeline Delivery
- Truck Offloading
- Warm and Cold Weather Packages Available
TRUCK LOADING LACT:
- Truck Grounding Device
- Ticket Printer
- Card Reader
PIPELINE LACT:
- Pipeline Pump(s)
- Pipeline Pressure Transmitter
- Flow Control with Variable Frequency Drives (VFDs)
MCC/CONTROL ROOM
- Control Panels
- Power Panels
- Transformers
- Motor Starters
- Switchgear
- HVAC Unit
CUSTOM AUTOMATION AND INTEGRATION
- Allen Bradley PLC
- Fisher ROC
- Flow Computers
- Custom Hardware
- Custom Software
- Temperature Averager
Standard LACT Specifications
- ANSI 150# Pipe, Valves, and Fittings
- Piping to B31.3 Standards
- Hydrotested
- 5% Radiography
- Class 1 Div 1 or Class 1 Div 2 Electrical
- Meets National Electrical Code